EXPLOSIONPROOF INDUSTRIAL LED LIGHTING FIXTURE.
ENCLOSED AND GASKETED. RETROFIT.
LE-LED-RT SERIES
- Class I Div.1/Groups C, D. Class II Div. 1 Groups E, F, G
Class I Zone 1/Groups II B, II A Class II Groups E, F, G
- Class I Div.1/Groups C, D. Class II Div. 1 Groups E, F, G
The LED lighting fixtures are available in two types of color temperatures, neutral white and cool white, has uniform ilumination, and is designed for interior or exterior use, using a LED arrangements can overcome 250 W HID light.

APPLICATIONS
- Series LE, Lighting fixtures designed for use where moisture, dust, dirt, corrosion and vibration may be present or where exist the possibility of water, wind, or snow.
- Lighting fixtures could be use in manufacturing plants, and certain chemical and petrochemical processing facilities, sewage treatment plants, offshore installations, warehouse, etc.
MATERIALS:
- Body and mounting: Die cast aluminum.
- Finish: Electrostatic powder coating epoxic/polyester. Minimum thickness 2 mils
- Saline chamber test to paint according to ASTM B117.
- Paint adhesion test according to ASTM 3359.
- Resistance to mechical impacts according to IK09 casing, thanks to its design that does not have elements susceptible to breakage.
- External hardware: Stainless steel.
- Refractor globe: Heat resistant prismatic globe
- Gaskets: Silicone for high temperatures.
- Guard: Diecast aluminum
- NPT threaded to ensure ground continuity.
CHARACTERISTICS:
- Photometric Distribution: IESNA Type II, Type III, and Type HB-90º.
- Minimal maintenance.
- Instant ignition.
- Operation at low temperatures.
- Low surface temperatures.
- LED system can save up to 80% in energy costs.
- 50,000 hours of life can provide more than 10 years of lighting without maintenance.
- Grounded housing
- Contains no mercury and hazardous chemical products.
- Operation temperatures: -30 ºC up to 50 ºC
- 4 Mounting types: Pendant, stanchion, ceiling, wall.
- Wet locations
- Explosionproof
- Dust-ignition proof
- Initial lumens 5% @ 25ºC.
- Protection against current variations through voltage supressor category C3 10 KV line-ground
- Real performance could vary as a result of application and enviroment
where the lighting fixture are installed.
All parameters are designed and measured under laboratory conditions at 25 ºC.
T5 temperature range for safe use in most hazardous enviroments.
Factory sealed: Refer to installations instructions for external seal requeriments.
Compliances:
- UL 844 UL 1598
CSA C22.2 No. 137
UL 8750 LED
NEMA 3, 3R, 4, 4X
NMX-J-307-2017
NMX-J-627-2009
NMX-J-529-2012