HAZARDOUS LOCATIONS INDUSTRIAL LED LIGHTING FIXTURE
ENCLOSED AND GASKETED. RETROFIT.
LH-LED SERIES
- Class I Div. 2/Groups A, B, C, D. Class II Div. 1 Groups E, F, G.
Class I Zone 2/Groups II C, II B, II A, Class II Groups E, F, G.
- Class I Div. 2/Groups A, B, C, D. Class II Div. 1 Groups E, F, G.
The LED lighting fixtures are neutral white and cool white, both has uniform illumination, and are designed for interior or exterior use, using a LED arrangements can overcome 1000 watts of HID light.
APPLICATIONS:
- Series LH-LED, lighting fixtures designed for use where moisture, dust, dirt, corrosion and vibration may be present or where exist the possibility of water, wind or snow.
- They can be use in ordinary location and in hazardous locations by the presence of flamable vapors, gases or combustible dust as defined by NEC (National Electric Code).
- Lighting fixtures could be use in manufacturing plants, certain chemical and petrochemical processing facilities, sewage treatment plants, offshore installations, warehouse, etc.
- For use indoor and outdoor.
MATERIAL:
- Body and mounting: Diecast aluminum.
- Finish: Electrostatic powder coating epoxic/polyester. Minimum thickness 2 mils
- Saline chamber test to paint according to ASTM B117
- Paint adhesion test according to ASTM 3359
- Resistance to mechanical impacts according to IK09 casing, thanks to Its design that does not have elements susceptible to breakage.
- External hardware: Stainless steel.
- Refractor globe: Polycarbonate resistant to UV.
- Gaskets: Silicone for high temperatures.
FEATURES:
- Photometric Distribution: IESNA Type I and Type V.
- External flaps provide great thermal transfer for a long life of LED, obtaining higher T-Raitings.
- Minimal maintenance.
- Instant ignition.
- Operation at low temperatures.
- Low surface temperatures.
- Controller with internal fuses for branch circuit protection.
- LED system can save up to 80% in energy costs.
- 50,000 hours of life can provide more than 10 years of lighting without maintenance.
- Contains no mercury and hazardous chemical products.
- Operation temperatures: -30 °C up to 50 °C.
- Protection agains current variations through voltage supressor category C3 10 KV line-ground.
- 5 Mounting types: Pendant, stanchion 25° and 90°, ceiling, wall.
- Wet locations
- Raintight
- lnitial lumens ±5% @ 25°C
- Dust-ignition proof
- Grounded housing
- Compliances:
- UL 844 UL 1598 C
- CSA C22.2 No. 137
- UL 8750 LED
- NEMA 3, 3R, 4, 4X.
- NMX-J-307-2017
- NMX-J-627-2009
- NMX-J-529-2012