HAZARDOUS LOCATIONS INDUSTRIAL LED LIGHTING FIXTURE

ENCLOSED AND GASKETED

LH-LED SERIES

    • Class I Div. 2/Groups A, B, C, D. Class II Div. 1 Groups E, F, G.
      Class I Zone 2/Groups II C, II B, II A, Class II Groups E, F, G.

    • The LED lighting fixtures are neutral white and cool white, both has uniform illumination, and are designed for interior or exterior use, using a LED arrangements can overcome 1000 watts of HID light.

APPLICATIONS:
    • Series LH-LED, lighting fixtures designed for use where moisture, dust, dirt, corrosion and vibration may be present or where exist the possibility of water, wind or snow.
    • They can be use in ordinary location and in hazardous locations by the presence of flamable vapors, gases or combustible dust as defined by NEC (National Electric Code).
    • Lighting fixtures could be use in manufacturing plants, certain chemical and petrochemical processing facilities, sewage treatment plants, offshore installations, warehouse, etc.
    • For use indoor and outdoor.

MATERIAL:
    • Body and mounting: Diecast aluminum.
    • Finish: Electrostatic powder coating epoxic/polyester. Minimum thickness 2 mils
    • Saline chamber test to paint according to ASTM B117
    • Paint adhesion test according to ASTM 3359
    • Resistance to mechanical impacts according to IK09 casing, thanks to Its design that does not have elements susceptible to breakage.
    • External hardware: Stainless steel.
    • Refractor globe: Polycarbonate resistant to UV.
    • Gaskets: Silicone for high temperatures.

FEATURES:
    • Photometric Distribution: IESNA Type I and Type V.
    • External flaps provide great thermal transfer for a long life of LED, obtaining higher T-Raitings.
    • Minimal maintenance.
    • Instant ignition.
    • Operation at low temperatures.
    • Low surface temperatures.
    • Controller with internal fuses for branch circuit protection.
    • LED system can save up to 80% in energy costs.
    • 50,000 hours of life can provide more than 10 years of lighting without maintenance.
    • Contains no mercury and hazardous chemical products.
    • Operation temperatures: -30 °C up to 50 °C.
    • Protection agains current variations through voltage supressor category C3 10 KV line-ground.
    • 5 Mounting types: Pendant, stanchion 25° and 90°, ceiling, wall.
    • Wet locations
    • Raintight
    • lnitial lumens ±5% @ 25°C
    • Dust-ignition proof
    • Grounded housing

  • Compliances:
  • UL 844  UL 1598 C
  • CSA C22.2 No. 137
  • UL 8750 LED
  • NEMA 3, 3R, 4, 4X.
  • NMX-J-307-2017
  • NMX-J-627-2009
  • NMX-J-529-2012